Title
Analiza ponašanja grupe elastičnih moždanika kod spregnutih nosača od čelika i betona
Creator
Spremić, Milan J., 1975-
Copyright date
2013
Object Links
Select license
Autorstvo-Nekomercijalno 3.0 Srbija (CC BY-NC 3.0)
License description
Dozvoljavate umnožavanje, distribuciju i javno saopštavanje dela, i prerade, ako se navede ime autora na način odredjen od strane autora ili davaoca licence. Ova licenca ne dozvoljava komercijalnu upotrebu dela. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc/3.0/rs/deed.sr_LATN Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
Other responsibilities
mentor
Buđevac, Dragan, 1954-
član komisije
Marković, Zlatko, 1968-
član komisije
Buđevac, Dragan, 1954-
član komisije
Marković, Zlatko, 1968-
član komisije
Marinković, Snežana, 1962-
Academic Expertise
Tehničko-tehnološke nauke
Faculty
Građevinski fakultet
Alternative title
The analysis of headed studs group behavior in composite steel-concrete beam
Publisher
[M. Spremić]
Format
PDF/A (179 listova)
description
Građevinarstvo-Spregnute konstrukcije od čelika i betona, Metalne konstrukcije / Civil Engineering-Composite steel and concrete structures, Steel structures
Abstract (sr)
Diskontinualni podužni smičući spoj ostvaren grupama moždanika je
jednostavno i široko rasprostranjeno rešenje za sprezanje čeličnih nosača i montažnih
armiranobetonskih ploča. Ovaj rad analizira mogućnost primene grupa moždanika sa
redukovanim rastojanjima između susednih moždanika u grupi. Osnovni cilj rada je da
se istraži mogućnost smanjenja rastojanja između susednih moždanika u grupi u odnosu
na minimalno propisana rastojanja. Smanjenje rastojanja između moždanika u grupi i
dimenzija grupe, omogućava izvođenje manjeg otvora u armiranobetonskoj montažnoj
ploči potrebnog za smeštaj moždanika. Prikazano je sopstveno eksperimentalno
istraživanje nosivosti grupa moždanika, sprovedeno na Građevinskom fakultetu
Univerziteta u Beogradu. Eksperimentalnim istraživanjem analizirana je mogućnost
primene grupe moždanika kod spregnutih greda u zgradarstvu. Ispitana je nosivost,
deformabilnost i ponašanje, podužnog smičućeg spoja ostvarenog grupama moždanika.
Glavni parametri analizirani u radu su: raspored moždanika u grupi, orijentacija grupe
moždanika u odnosu na pravac podužne sile smicanja i međusobno rastojanje
moždanika. Istraživanjem je obuhvaćeno pet različitih dispozicija grupa od četiri
elastična moždanika sa glavom, kod kojih su međusobna rastojanja manja od minimalno
propisanih rastojanja u Evrokodu 4. Cilj istraživanja je i da se utvrdi kako smanjenje
minimalnih propisanih rastojanja između moždanika utiče na ponašanje, odnosno
nosivost, duktilnost i ukupne deformacije podužnog smičućeg spoja. Korišćeni
materijali, polazne pretpostavke i postupak ispitivanja su u skladu sa Evrokodom 4.
Metodom konačnih elemenata simulirano je eksperimentalno istraživanje a kalibrisan
numerički model sa eksperimentom je poslužio za izvođenje zaključaka o ponašanju
veze ostvarene grupom moždanika sa glavom. Uočeni su i definisani modeli loma koji
se mogu javiti u podužnim smičućim spojevima, formiranim grupama moždanika. Na
uočenim modelima loma definisana su granična stanja nosivosti grupe moždanika.
iv
Pomoću numeričkih modela urađena je i parametarska analiza koja je obuhvatila
različite prečnike i grupe moždanika...
Abstract (en)
Discontinuous shear connection with groups of headed studs is simple and
widespread solution for connection between steel beam and precast concrete element.
This thesis analyzes the possible applications of headed studs group with reduced
distances between adjacent headed studs in the group. The main objective of this study
was to investigate the possibility of reducing the spacing between adjacent headed studs
in the group compared to the minimum required in Eurocode 4. Reducing the distance
between the headed studs in the group and the dimensions of the group, would allow
construction of a smaller hole in the reinforced concrete precast plate needed to
accommodate the headed studs. The paper presents the results of the experimental
research conducted on push-out tests at the Faculty of Civil Engineering at the
University of Belgrade. Throughout the experiment there has been analyzed the
possibility of using the headed studs group in composite beams for buildings. The
capacity, deformability and behavior of shear connection with grouped headed studs
was investigated (analyzed). A shape of group arrangement along with its orientation to
the applied load and distance between the studs were variables considered. The study
includes five different groups of four headed studs, with the distance between headed
studs less than the minimum distances required in Eurocode 4. The aim of the research
is to determine how the reduce of the minimum required distance between the headed
studs affects to the behavior, shear capacity, ductility and total longitudinal shear
deformation of the shear connection. The materials, initial assumptions and test set up
are in accordance with Eurocode 4. The FEM model is used to simulate the experiment.
Calibrated FEM models with push-out tests were used to draw conclusions about the
behavior of shear connection with group of headed studs. The fracture models which
can occur in longitudinal shear connection with headed studs group were identified and
defined in the paper. Ultimate limit state for headed stud group based on the fracture
models is defined. Parametric analysis, which included a models with different
diameters of headed studs and layout of groups were performed by numerical models.
vi
Based on the results, the recommendations were derived for determining the shear
capacity of the headed studs group, when the distance between studs is less than
required by Code. The reduction coefficient was suggested to determine the shear
capacity of the headed studs group. Derived recommendations can be applied to shear
connections in composite steel-concrete beams applied in buildings...
Authors Key words
moždanici sa glavom, grupa moždanika, spregnuti nosač od čelika i
betona, prefabrikovane betonske ploče
Authors Key words
headed studs, group arrangement of stud connectors, steel-concrete
composite beams, prefabricated concrete slab
Classification
62
Subject
Spregnute konstrukcije
Type
Tekst
Abstract (sr)
Diskontinualni podužni smičući spoj ostvaren grupama moždanika je
jednostavno i široko rasprostranjeno rešenje za sprezanje čeličnih nosača i montažnih
armiranobetonskih ploča. Ovaj rad analizira mogućnost primene grupa moždanika sa
redukovanim rastojanjima između susednih moždanika u grupi. Osnovni cilj rada je da
se istraži mogućnost smanjenja rastojanja između susednih moždanika u grupi u odnosu
na minimalno propisana rastojanja. Smanjenje rastojanja između moždanika u grupi i
dimenzija grupe, omogućava izvođenje manjeg otvora u armiranobetonskoj montažnoj
ploči potrebnog za smeštaj moždanika. Prikazano je sopstveno eksperimentalno
istraživanje nosivosti grupa moždanika, sprovedeno na Građevinskom fakultetu
Univerziteta u Beogradu. Eksperimentalnim istraživanjem analizirana je mogućnost
primene grupe moždanika kod spregnutih greda u zgradarstvu. Ispitana je nosivost,
deformabilnost i ponašanje, podužnog smičućeg spoja ostvarenog grupama moždanika.
Glavni parametri analizirani u radu su: raspored moždanika u grupi, orijentacija grupe
moždanika u odnosu na pravac podužne sile smicanja i međusobno rastojanje
moždanika. Istraživanjem je obuhvaćeno pet različitih dispozicija grupa od četiri
elastična moždanika sa glavom, kod kojih su međusobna rastojanja manja od minimalno
propisanih rastojanja u Evrokodu 4. Cilj istraživanja je i da se utvrdi kako smanjenje
minimalnih propisanih rastojanja između moždanika utiče na ponašanje, odnosno
nosivost, duktilnost i ukupne deformacije podužnog smičućeg spoja. Korišćeni
materijali, polazne pretpostavke i postupak ispitivanja su u skladu sa Evrokodom 4.
Metodom konačnih elemenata simulirano je eksperimentalno istraživanje a kalibrisan
numerički model sa eksperimentom je poslužio za izvođenje zaključaka o ponašanju
veze ostvarene grupom moždanika sa glavom. Uočeni su i definisani modeli loma koji
se mogu javiti u podužnim smičućim spojevima, formiranim grupama moždanika. Na
uočenim modelima loma definisana su granična stanja nosivosti grupe moždanika.
iv
Pomoću numeričkih modela urađena je i parametarska analiza koja je obuhvatila
različite prečnike i grupe moždanika...
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.