Title
Uticaj hirurške tehnike ugradnje i mikro i makro dizajna implantata na njihovu stabilnost u bočnom segmentu gornje vilice
Creator
Ćalasan, Dejan, 1975-
Copyright date
2014
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 02.12.2014.
Other responsibilities
mentor
Marković, Aleksa, 1964-
član komisije
Čolić, Snježana, 1963-
član komisije
Stojčev-Stajčić, Ljiljana, 1966-
član komisije
Mirković, Siniša, 1969-
Academic Expertise
Medicinske nauke
University
Univerzitet u Beogradu
Faculty
Stomatološki fakultet
Alternative title
Effect of surgical technique and implant micro and macro design on stability of implants placed in posterior maxilla
Publisher
[ D. I. Ćalasan]
Format
162 lista
description
stomatološke nauke - oralna hirurgija / Dental Sciences - Oral surgery
Abstract (sr)
Odgovarajuća primarna stabilnost implantata je osovni faktor koji utiče na
dugotrajan uspeh endoosealnih implantata, što zavisi od dijametra i dužine implantata,
oblika tela implantata, karakteristika navoja implantata (makro dizajn), primenjene hirurške
tehnike, kao i od kvaliteta i količine raspoložive kosti. Primarnu stabilnost implantata je
teško postići u bočnim segmentima gornje vilice zbog male gustine kosti u ovoj regiji.
Kako su kvalitet i količina kosti faktori koji su već prisutni, u ovoj doktorskoj disertaciji
ispitivan je uticaj različitih hirurških tehnika, makro i mikro dizajna implantata na
poboljšanje stabilnosti implantata u kosti male gustine.
Cilj doktorske disertacije je bio ispitati i uporediti vrednosti implantne stabilnosti
između implantata sa samourezujućim i neurezujućim navojima ugrađenih nakon
preparacije ležišta metodom lateralne kondenzacije i standardnom tehnikom u kost male
gustine. Takođe, ispitati i uporediti vrednosti implantne stabilnosti između implantata sa
hidrofobnom i implantata sa hidrofilnom površinom ugrađenih u kost male gustine.
Preduzeta su eksperimentalna i klinička istraživanja.
U sprovedenoj „in vitro“ studiji korišćena su svinjska rebra uniforme debljine
koritkalnog sloja od 2 mm radi simulacije klase D3 i D4 po Carl-u i Misch-u humane
vilične kosti. Prema hirurškoj tehnici za peparaciju ležišta implantata (lateralna
kondenzacija kosti i standardna tehnika) i makro dizajnu implantata (samourezujući i
neurezujući), uzorci kosti su metodom slučajnog izbora bili podeljeni u 4 grupe čime je bilo
omogućeno ispitivanje svih kombinacija testiranih faktora. Merenje implantatne stabilnosti
vršeno je u termostatom kontrolisanom vodenom kupatilu metodom analize rezonantne
frekvencije (engl. Resonance Frequency Analysis RFA).
U kliničku studiju je bilo uključeno ukupno 46 pacijenata (26 ženskog i 20 muškog
pola) prosečne starosti 39.3 godina i kod njih je ugrađeno ukupno 144 implantata i to: 48
samourezujućih implantata (24 u ležišta preparirana lateralnom kondenzacijom kosti i 24 u
ležišta preparirana standardnom tehnikom), 48 neurezujućih implantata (24 u ležišta
preparirana lateralnom kondenzacijom kosti i 24 u ležišta preparirana standardnom
tehnikom), 24 implantata hidrofilne i 24 implantata hidrofobne površine u ležišta
preparirana standardnom tehnikom...
Abstract (en)
Sufficient primary implant stability is very important factor that affects long-term
implant success and depends on diameter and length of the implant, shape of implant body,
features of implant threads (macro design), surgical technique used as well as on the quality
and quantity of the available jaw bone. Primary stability is hard to achieve in posterior
maxilla due to low density of bone in this region. Since the quality and quantity of the jaw
bone are factors that are already present, the effect of surgical techniques, implant's macro
and micro designs on improvement of implant stability in low-density bone were assessed
in this doctoral dissertation.
The aim was to investigate and compare implant stability between self-tapping and
non self-tapping implants inserted in low-density bone following lateral bone condensing
or standard surgical techniques. Also, to investigate and compare implant stability
between implants with hydrophobic and hydrophilic surfaces inserted into the low-density
bone.
Experimental and clinical study were performed.
In the „in vitro“ study, pig ribs with uniform thickness of corticalis of 2 mm were
used to simulate jaw bone type D3 or D4 according to Carl and Misch classification. With
regards to surgical technique (lateral bone condensing or standard surgical technique) and
implant macro design (self-tapping and non self-tapping), bone samples were randomly
divided into 4 test groups to allow investigation of all possible combinations of the tested
factors. Implant stability was measured in thermostat controlled water bath using
Resonance Frequency Analysis (RFA) as a method of measurement.
A total of 46 patients (26 females and 20 males) with a mean age of 39.3 years were
included in the clinical study and they received a total of 144 implants in the following
way: 48 self-tapping implants (24 following lateral bone condensation and 24 following
standard surgical technique), 48 non self-tapping implants (24 following lateral bone
condensation and 24 following standard surgical technique), 24 implants with hydrophilic
surface and 24 implants with hydrophobic surface following standard surgical technique...
Authors Key words
hirurška tehnika ugradnje implantata , kost male gustine, mikro dizajn
implantata, makro dizajn implantata, stabilnost implantata
Authors Key words
implant placement surgical technique, low-density bone, implant micro
design, implant macro design, implant stability
Classification
616.314-089.843(043.3)
Type
Tekst
Abstract (sr)
Odgovarajuća primarna stabilnost implantata je osovni faktor koji utiče na
dugotrajan uspeh endoosealnih implantata, što zavisi od dijametra i dužine implantata,
oblika tela implantata, karakteristika navoja implantata (makro dizajn), primenjene hirurške
tehnike, kao i od kvaliteta i količine raspoložive kosti. Primarnu stabilnost implantata je
teško postići u bočnim segmentima gornje vilice zbog male gustine kosti u ovoj regiji.
Kako su kvalitet i količina kosti faktori koji su već prisutni, u ovoj doktorskoj disertaciji
ispitivan je uticaj različitih hirurških tehnika, makro i mikro dizajna implantata na
poboljšanje stabilnosti implantata u kosti male gustine.
Cilj doktorske disertacije je bio ispitati i uporediti vrednosti implantne stabilnosti
između implantata sa samourezujućim i neurezujućim navojima ugrađenih nakon
preparacije ležišta metodom lateralne kondenzacije i standardnom tehnikom u kost male
gustine. Takođe, ispitati i uporediti vrednosti implantne stabilnosti između implantata sa
hidrofobnom i implantata sa hidrofilnom površinom ugrađenih u kost male gustine.
Preduzeta su eksperimentalna i klinička istraživanja.
U sprovedenoj „in vitro“ studiji korišćena su svinjska rebra uniforme debljine
koritkalnog sloja od 2 mm radi simulacije klase D3 i D4 po Carl-u i Misch-u humane
vilične kosti. Prema hirurškoj tehnici za peparaciju ležišta implantata (lateralna
kondenzacija kosti i standardna tehnika) i makro dizajnu implantata (samourezujući i
neurezujući), uzorci kosti su metodom slučajnog izbora bili podeljeni u 4 grupe čime je bilo
omogućeno ispitivanje svih kombinacija testiranih faktora. Merenje implantatne stabilnosti
vršeno je u termostatom kontrolisanom vodenom kupatilu metodom analize rezonantne
frekvencije (engl. Resonance Frequency Analysis RFA).
U kliničku studiju je bilo uključeno ukupno 46 pacijenata (26 ženskog i 20 muškog
pola) prosečne starosti 39.3 godina i kod njih je ugrađeno ukupno 144 implantata i to: 48
samourezujućih implantata (24 u ležišta preparirana lateralnom kondenzacijom kosti i 24 u
ležišta preparirana standardnom tehnikom), 48 neurezujućih implantata (24 u ležišta
preparirana lateralnom kondenzacijom kosti i 24 u ležišta preparirana standardnom
tehnikom), 24 implantata hidrofilne i 24 implantata hidrofobne površine u ležišta
preparirana standardnom tehnikom...
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.