Title
Primena oksidacije organo-tiofosfatnih pesticida u metodama za njihovu detekciju na bazi inhibicije acetilholinesteraze
Creator
Lazarević-Pašti, Tamara, 1984-
Copyright date
2012
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 31.05.2012.
Other responsibilities
mentor
Mandić, Ljuba, 1953-
mentor
Vasić, Vesna
član komisije
Vrvić, Miroslav, 1952-
Academic Expertise
Prirodno-matematičke nauke
University
Univerzitet u Beogradu
Faculty
Hemijski fakultet
Alternative title
Application of organothiophosphate pesticides oxidation in methods for their detection based on acetylcholinesterase inhibition
Publisher
Beograd : [T. D. Lazarević-Pašti]
Format
PDF/A (143 lista)
description
Prirodno-matematičke nauke - biohemija / Natural sciences and mathematics - biochemistry
Abstract (sr)
Ispitana je inhibicija slobodne acetilholinesteraze (AChE) odabranim organotiofosfatima (OP) (diazinon, malation, hlorpirifos, azinfos-metil, forat) i njihovim oksoanalozima (diazokson, malaokson, hlorpirifos-okson, azinfos-metil-okson, forat-okson), pri čemu su optimizovani uslovi za detekciju najniže koncentracije tih jedinjenja primenom AChE testa. Određene su IC50 vrednosti za sva navedena jedinjenja. U cilju povećanja osetljivosti AChE testa, ispitivani organo-tiofosfati prevedeni su u okso-analoge u prisustvu enzima mijeloperoksidaze (MPO). To je potvreno pomoću
UPLC i GC/MS analize. Nastali oksidacioni proizvodi stabilni su najmanje 1h. Maksimalne koncentracije oksona dobijaju se kada se organo-tiofosfati inkubiraju sa 100 nM MPO u prisustvu H2O2 koncentracije 50 μM, pri pH 6, na temperaturi 25 °C u toku 10 minuta. Oksidacija OP u prisustvu MPO pod navedenim uslovima primenjena je u modifikaciji metode za detekciju OP na bazi inhibicije AChE. Određena je granica detekcije modifikovane metode, kao i efikasnost oksidacije i njena primena na smešu OP. Gore navedeni organo-tiofosfati prevedeni su u odgovarajue oksone i pomoću elektrohemijski generisanih halogena. Proizvodi koji nastaju identifikovani su kao oksoni pomoću UPLC analize. Utvrđeno je da je najefikasnija oksidacija elektrogenerisanim bromom u toku 15 minuta. Određena je i granica detekcije AChE testa za odreivanje OP kada su OP oksidovani elektrohemijski generisanim bromom...
Abstract (en)
The inhibition of acetylcholinesterase in the presence of selected organothiophosphates (diazinon, malathion, chlorpyrifos, azinphos-methyl, phorate) and
their oxo-analogues (diazoxon, malaoxon, chlorpyrifos-oxon, azinphos-methyl-oxon,
phorate-oxon) was examined. Experimental conditions were optimized to detect the lowest
posible concentrations of these compounds using AChE test. IC50 values were determined
for all the mentioned compounds.
Investigated organothiophosphates have been converted into their oxo-analogues in
the presence of the enzyme myeloperoxidase. Oxidation products were detected using
UPLC and GC/MS analysis. It was found that the products are stable within minimum 1h.
In order to optimize oxidation procedure and achieve maximum concentrations of oxons,
the optimal concentrations of H2O2 (50 μM) and MPO (100 nM) were determined. Also,
the optimal incubation time of OPs and MPO (10 min), as well as the optimal pH (6) and
temperature (25 °C) were estimated. Oxidation of OPs in the presence of MPO under
optimal conditions was applied as a modification of the method for detecting OP using
AChE test. The detection limits were determined for the modified method, as well as the
efficiency of oxidation and its application for the analysi of sintetic mixture of OPs.
Examined organothiophosphates have been converted into their oxo-forms using
electrochemically generated halogens. Products have been identified as oxons using UPLC
analysis. It was found that the the most efficient oxidation of OPs was carried out by after
15 minutes of oxidation with electrogenerated bromine. Detection limits were determined,
too.
Authors Key words
Organofosfati, pesticidi, biosenzori, oksidacija, acetilholin-esteraza,
mijeloperoksidaza, detekcija
Authors Key words
Organophosphate, pesticide, biosensor, oxidation, acetylcholinesterase,
myeloperoxidase, detection
Classification
577.1(043.3)
Subject
Organofosfatni pesticidi
Subject
Acetilholinesteraza
Type
Tekst
Abstract (sr)
Ispitana je inhibicija slobodne acetilholinesteraze (AChE) odabranim organotiofosfatima (OP) (diazinon, malation, hlorpirifos, azinfos-metil, forat) i njihovim oksoanalozima (diazokson, malaokson, hlorpirifos-okson, azinfos-metil-okson, forat-okson), pri čemu su optimizovani uslovi za detekciju najniže koncentracije tih jedinjenja primenom AChE testa. Određene su IC50 vrednosti za sva navedena jedinjenja. U cilju povećanja osetljivosti AChE testa, ispitivani organo-tiofosfati prevedeni su u okso-analoge u prisustvu enzima mijeloperoksidaze (MPO). To je potvreno pomoću
UPLC i GC/MS analize. Nastali oksidacioni proizvodi stabilni su najmanje 1h. Maksimalne koncentracije oksona dobijaju se kada se organo-tiofosfati inkubiraju sa 100 nM MPO u prisustvu H2O2 koncentracije 50 μM, pri pH 6, na temperaturi 25 °C u toku 10 minuta. Oksidacija OP u prisustvu MPO pod navedenim uslovima primenjena je u modifikaciji metode za detekciju OP na bazi inhibicije AChE. Određena je granica detekcije modifikovane metode, kao i efikasnost oksidacije i njena primena na smešu OP. Gore navedeni organo-tiofosfati prevedeni su u odgovarajue oksone i pomoću elektrohemijski generisanih halogena. Proizvodi koji nastaju identifikovani su kao oksoni pomoću UPLC analize. Utvrđeno je da je najefikasnija oksidacija elektrogenerisanim bromom u toku 15 minuta. Određena je i granica detekcije AChE testa za odreivanje OP kada su OP oksidovani elektrohemijski generisanim bromom...
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.