Title
Uticaj izbora scintilacionog kristala na odziv detektora kod pet uređaja
Creator
Antić, Vojislav M., 1973-
Copyright date
2014
Object Links
Select license
Autorstvo 3.0 Srbija (CC BY 3.0)
License description
Dozvoljavate umnožavanje, distribuciju i javno saopštavanje dela, i prerade, ako se navede ime autora na način odredjen od strane autora ili davaoca licence, čak i u komercijalne svrhe. Ovo je najslobodnija od svih licenci. Osnovni opis Licence: http://creativecommons.org/licenses/by/3.0/rs/deed.sr_LATN Sadržaj ugovora u celini: http://creativecommons.org/licenses/by/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 20.03.2015.
Other responsibilities
mentor
Stanković, Koviljka
član komisije
Marinković, Predrag, 1951-
član komisije
Obradović, Vladimir, 1948-
član komisije
Ciraj-Bjelac, Olivera, 1972-
član komisije
Popović, Dejan V.
Academic Expertise
Tehničko-tehnološke nauke
University
Univerzitet u Beogradu
Faculty
Elektrotehnički fakultet
Alternative title
Influence of the scintillation crystal option on the detector response of pet devices
Publisher
[ V. Antić]
Format
116 listova
description
Elektrotehnika - Nuklearna tehnika, elektrotehnički materijali / Electrical Engineering - Nuclear engineering, materials in electrical engineering
Abstract (sr)
Pozitronska emisiona tomografija (PET) je tehnologija koja pruža jedinstvene i izuzetne mogućnosti u funkcionalnoj dijagnostici u smislu da se pomoću do sada najefikasnije i najpouzdanije metode dolazi do informacije o biohemijskoj aktivnosti i ćelijskom metabolizmu u telu, određivanjem tačne lokalizacije i vršenjem semikvantitativne procene distribucije radioaktivne supstance. U ovom radu porede se karakteristike nedavno uvedenih kristala na bazi lutecijuma (LYSO) sa karakteristikama konvencionalnih bizmut-orto-germanat (BGO) scintilatora. Ispitane su sledeće scintilacione karakteristike PET kristala: osetljivost, energetska rezolucija, svetlosni prinos, svojstvena energetska rezolucija, atenuacija γ zraka kroz scintilacione kristale, radijaciona dužina, Molijerov radijus, vreme gašenja svetlosnog impulsa u scintilacionom kristalu, vreme preleta (TOF eng. „Time of Flight“) i refrakcioni indeks. Razmatran je uticaj fizičko-hemijskih i električnih osobina scintilatora na odziv detektora, uparenost svih parametara PET scintilatora, dimenzionisanje detektorskih kristala, „organizacija“ u PET blok detektore i povezivanje sa PET fotomultiplikatorima, sve u cilju dobijanja što kvalitetnije PET medicinske slike.
Abstract (en)
Positron emission tomography (PET) is a technology that provides unique and exquisite possibilities in functional diagnostics, in the sense that it is the most efficient and most reliable method for obtaining information about biochemical activity and cellular metabolism in the body, by determining exact localization and performing semi-quantitative assessment of the distribution of a radioactive tracer. This work compares the characteristics of recently introduced lutetium based crystals (LYSO) to those of conventionally used bismuth-ortho-germanate scintillators (BGO) The following characteristis of PET crystals have been investigated: energy resolution, scintillation decay time, sensitivity, light yield, intrinsic energy resolution, atenuation of gama radiation in scintilation crystal, radiation length, time of flight, Moliere radius, refraction index. The influence of scintilators’ physical, chemical and electric properties on the detector response are considered and analyzed, as well as the PET scintilation parameters pairing, dimensioning of detector crystals, their organizing in PET block detectors and linking to PET photomultipliers, all in order to obtain a higher quality of PET medical image.
Authors Key words
pozitronska emisiona tomografija, scintilacioni kristal, odziv detektora
Authors Key words
positron emission tomography, scintillation crystal, detector response
Type
Tekst
Abstract (sr)
Pozitronska emisiona tomografija (PET) je tehnologija koja pruža jedinstvene i izuzetne mogućnosti u funkcionalnoj dijagnostici u smislu da se pomoću do sada najefikasnije i najpouzdanije metode dolazi do informacije o biohemijskoj aktivnosti i ćelijskom metabolizmu u telu, određivanjem tačne lokalizacije i vršenjem semikvantitativne procene distribucije radioaktivne supstance. U ovom radu porede se karakteristike nedavno uvedenih kristala na bazi lutecijuma (LYSO) sa karakteristikama konvencionalnih bizmut-orto-germanat (BGO) scintilatora. Ispitane su sledeće scintilacione karakteristike PET kristala: osetljivost, energetska rezolucija, svetlosni prinos, svojstvena energetska rezolucija, atenuacija γ zraka kroz scintilacione kristale, radijaciona dužina, Molijerov radijus, vreme gašenja svetlosnog impulsa u scintilacionom kristalu, vreme preleta (TOF eng. „Time of Flight“) i refrakcioni indeks. Razmatran je uticaj fizičko-hemijskih i električnih osobina scintilatora na odziv detektora, uparenost svih parametara PET scintilatora, dimenzionisanje detektorskih kristala, „organizacija“ u PET blok detektore i povezivanje sa PET fotomultiplikatorima, sve u cilju dobijanja što kvalitetnije PET medicinske slike.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.