Title
Fazi optimizacija u hidrodinamičkoj analizi za potrebe projektovanja sistema odbrane od podzemnih voda
Creator
Bajić, Dragoljub I.
Copyright date
2015
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 26.01.2016.
Other responsibilities
mentor
Polomčić, Dušan.
član komisije
Jemcov, Igor.
član komisije
Dragišić, Veselin.
član komisije
Dašić, Tina, 1970-
Academic Expertise
Tehničko-tehnološke nauke
University
Univerzitet u Beogradu
Faculty
Fakultet organizacionih nauka
Alternative title
Fuzzy optimization in the hydrodynamic analysis for the purposes of groundwater control system design
Publisher
[D. Bajić]
Format
X, 293, lista
description
Geološko inženjerstvo - vodosnabdevanje i menadžment podzemnih voda / Geological Engineering - water supply and groundwater management
Abstract (sr)
Sistemi za odbranu od podzemnih voda se koriste za zaštitu hidrotehničkih objekata, priobalja, meliorativnih područja, naselja, rudnika, predstavljajući značajne segmente bez kojih bi funkcionalnost ovih objekata bila dovedena u pitanje. Posebno složeni sistemi odbrane od podzemnih voda se karakterišu kod ležišta mineralnih sirovina, imajući u vidu njihovu dinamičnost, koja se ogleda u stalnom širenju ležišta, kao i činjenicu da ova ležišta prodiru duboko u stensku masu različitog strukturnog tipa poroznosti, a time i u podzemne vode, različite po hidrodinamičkim osobinama.
Površinski kop „Buvač“, uzev u obzir njegove karakteristike, predstavlja složen sistem propraćen intenzivnim promenama koje se dešavaju tokom eksploatacije mineralnih sirovina, a značajnim i u pogledu problematike odbrane od podzemnih voda. Upravo ovakav sistem zahteva stalno prilagođavanje novonastalim uslovima, što uslovljava uspostavljanje i razvoj metodskih postupaka za uspešnu odbranu od podzemnih voda u uslovima kontinuiranih promena. Parcijalni pristup rešavanja ove problematike najčešće ne dovodi do efikasnog, odnosno, do optimalnog rešenja sistema odbrane od podzemnih voda. Integracijom različitih faktora koji podrazumevaju tehničke karakteristike sistema odbrane od podzemnih voda, uticaje na životnu sredinu, ekonomske kriterijume i njihove podkriterijume, moguće je sveobuhvatnije sagledati predmetnu problematiku.
U cilju rešavanja ovog zadatka primenjeni su različiti postupci: metoda hidrodinamičkog modeliranja režima podzemnih voda, kombinacija teorije fazi logike i geostatistike i teorije fazi logike i višekriterijumske optimizacije.
Za projektovanje i izbor karakteristika sistema odbrane od podzemnih voda primenjena je metoda hidrodinamičkog modeliranja režima podzemnih voda. Tako su definisani elementi sistema za odbranu od podzemnih voda, njihove karakteristike (npr. kapaciteti bunara), njihov raspored u planu i profilu, redosled izvođenja drenažnih objekata, a sve to je povezano sa šemom i dinamikom izvođenja pripremnih i eksploatacionih radova na površinskom kopu.
Abstract (en)
Groundwater control systems are used to safeguard hydraulic structures, riparian lands, hydraulic reclamation zones, populated areas, mining operations, and the like. They constitute important functional segments, without which the safety of such structures or areas would be compromised. Especially complex protection systems against groundwater are found in mining operations, given the dynamics resulting from constant expansion and the fact that such operations reach deep into rock masses of varying structural porosity and, consequently, come into contact with groundwaters that feature different hydrodynamic properties.
In view of its characteristics, the open-pit mine “Buvač” is an intricate system that undergoes major changes during the course of ore extraction, which are coupled with significant issues relating to groundwater. In such circumstances, a groundwater control system needs to continually adapt to new conditions and methodical procedures have to be developed for effective protection against groundwater in a constantly changing environment. A partial approach seldom leads to an effective or optimal protection solution. A comprehensive study of the problem is needed, which integrates various factors, including technical characteristics of the protection system, environmental impact, and economic criteria and sub-criteria.
Different methods are applied to address the task: hydrodynamic modeling of the groundwater regime, a combination of the fuzzy logic theory and geostatistics, and the fuzzy logic theory and multicriteria optimization.
Hydrodynamic modeling of the groundwater regime was the method used to design and select the characteristics of the protection system against groundwater. This included the definition of the protection system components, their characteristics (e.g. well capacity), distribution in plan view and elevation, and sequence of construction of drainage components, all closely linked with the configuration and timetable of preparatory and extraction activities in the open-pit mine.
Authors Key words
upravljanje podzemnim vodama, procena hidrogeoloških parametara, hidrodinamički model, fazi logika, trougaoni fazi brojevi, znanje eksperta, optimizacija
Authors Key words
groundwater management, assessment of hydrogeological parameters, hydrodynamic model, fuzzy logic, triangular fuzzy numbers, expert judgment, optimization
Classification
622.586:510.644(043.3)
Type
Tekst
Abstract (sr)
Sistemi za odbranu od podzemnih voda se koriste za zaštitu hidrotehničkih objekata, priobalja, meliorativnih područja, naselja, rudnika, predstavljajući značajne segmente bez kojih bi funkcionalnost ovih objekata bila dovedena u pitanje. Posebno složeni sistemi odbrane od podzemnih voda se karakterišu kod ležišta mineralnih sirovina, imajući u vidu njihovu dinamičnost, koja se ogleda u stalnom širenju ležišta, kao i činjenicu da ova ležišta prodiru duboko u stensku masu različitog strukturnog tipa poroznosti, a time i u podzemne vode, različite po hidrodinamičkim osobinama.
Površinski kop „Buvač“, uzev u obzir njegove karakteristike, predstavlja složen sistem propraćen intenzivnim promenama koje se dešavaju tokom eksploatacije mineralnih sirovina, a značajnim i u pogledu problematike odbrane od podzemnih voda. Upravo ovakav sistem zahteva stalno prilagođavanje novonastalim uslovima, što uslovljava uspostavljanje i razvoj metodskih postupaka za uspešnu odbranu od podzemnih voda u uslovima kontinuiranih promena. Parcijalni pristup rešavanja ove problematike najčešće ne dovodi do efikasnog, odnosno, do optimalnog rešenja sistema odbrane od podzemnih voda. Integracijom različitih faktora koji podrazumevaju tehničke karakteristike sistema odbrane od podzemnih voda, uticaje na životnu sredinu, ekonomske kriterijume i njihove podkriterijume, moguće je sveobuhvatnije sagledati predmetnu problematiku.
U cilju rešavanja ovog zadatka primenjeni su različiti postupci: metoda hidrodinamičkog modeliranja režima podzemnih voda, kombinacija teorije fazi logike i geostatistike i teorije fazi logike i višekriterijumske optimizacije.
Za projektovanje i izbor karakteristika sistema odbrane od podzemnih voda primenjena je metoda hidrodinamičkog modeliranja režima podzemnih voda. Tako su definisani elementi sistema za odbranu od podzemnih voda, njihove karakteristike (npr. kapaciteti bunara), njihov raspored u planu i profilu, redosled izvođenja drenažnih objekata, a sve to je povezano sa šemom i dinamikom izvođenja pripremnih i eksploatacionih radova na površinskom kopu.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.