Title
Побољшање преношења топлоте у акумулатору топлоте са фазно променљивим материјалом као испуном
Creator
Rudonja, Nedžad R., 1982-
Copyright date
2016
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Committee report
Theses Type
Doktorska disertacija
description
Datum odbrane: 08.06.2016.
Other responsibilities
mentor
Komatina, Mirko, 1963-
član komisije
Banjac, Miloš, 1968-
član komisije
Gojak, Milan, 1960-
član komisije
Antonijević, Dragi.
član komisije
Živković, Goran.
Academic Expertise
Tehničko-tehnološke nauke
University
Univerzitet u Beogradu
Faculty
Mašinski fakultet
Alternative title
Heat transfer enhancement in the thermal energy storage filled by phase change material
Publisher
[Н. Р. Рудоња]
Format
VIII, 176 листова
description
Машинство - Термомеханика / Mechanical engineering - Thermomechanics
Abstract (sr)
Отежано преношење топлоте у акумулаторима топлоте са фазно
променљивим материјалом као испуном, које се јавља као последица мале
топлотне проводљивости фазно променљивих материјала који се користе
на температурском опсегу до 200 C° , представља главну препреку у
примени акумулатора топлоте у којима се акумулација топлоте остварује
на рачун промене фазе радног медијума. Поред типова акумулатора
топлоте и прегледа потенцијалних, односно коришћених фазно
променљивих материјала, разматране су методе за побољшање
преношења топлоте, тј. за превазилажење проблема мале топлотне
проводљивости материјала. Као најпоузданији метод за поспешивање
преношења топлоте се показало повећање површи за размену топлоте, тј.
површи која је у контакту са фазно променљивим материјалом. Као фазно
променљиви материјал коришћен је парафин комерцијалног назива Е53.
Побољшање преношења топлоте је праћено преко смањења времена
топљења парафина, тј. повећања брзине промене фазе, односно
временског периода у коме се достиже температура промене фазе
парафина. За разлику од досадашњих истраживања, у којима је повећање
оствареног побољшања преношења топлоте посматрано у функцији од
броја ребара или неке карактеристичне димензије ребра (висина,
пречник, дужина и сл.), у овом раду је побољшање доведено у корелацију
са фактором оребрења. У оквиру дисертације је осмишљен физички
модел акумулатора топлоте испуњеног фазно променљивим материјалом
за три вредности фактора оребрења, тј. за три варијанте акумулатора
топлоте. Уведени физички модел акумулатора топлоте описан је
одговарајућим математичким моделом у који су имплементиране
претпоставке неопходне за решавање дефинисаног система једначина...
Abstract (en)
Impaired heat transfer in thermal energy storage (TES) with phase change
material (PCM) as a filling, which occurs as a result of low thermal conductivity
of the phase-change materials used for storing thermal energy up to 200 C° ,
represents a major obstacle in the implementation of the TES in which the heat
accumulation is realized as a consequence of the working medium phase
change. Beside review of present thermal energy storages types and potential
one, respectively used PCMs, methods for enhancing heat transfer were
considered, i.e. method for overcoming the problem of low thermal
conductivity material. As the most reliable method for enhancing heat transfer,
the increase of heat transfer surface was found, i.e. the surface that is in the
contact with PCM. The commercial paraffin E53 was used as the PCM. The
enhancement of heat transfer is accompanied by the decrease of the paraffin
melting time, i.e. increase of the phase change rate, respectively the period in
which the temperature of the phase change of the paraffin is reached. Unlike
previous studies, where achieved heat transfer increase was analyzed as a
function of the number of fins or some fin characteristic dimension (height,
diameter, length, etc.), in this thesis the heat transfer improvement was into
correlated with of the finned surface factor. Within this thesis the physical
model of the thermal energy storage filled by PCM was conceived for three
values of the finned surface factor, i.e. for the three variants of the TES. The
introduced physical model of the TES was described by corresponding
mathematical model in which the necessary assumptions for solving the
defined system of equations were implemented...
Authors Key words
акумулатор топлоте, фазно променљив материјал,
парафин, нумеричко моделирање
Authors Key words
thermal energy storage, phase-change material, paraffin,
numerical modeling.
Classification
621.1.016.4:697.329(043.3)
Type
Tekst
Abstract (sr)
Отежано преношење топлоте у акумулаторима топлоте са фазно
променљивим материјалом као испуном, које се јавља као последица мале
топлотне проводљивости фазно променљивих материјала који се користе
на температурском опсегу до 200 C° , представља главну препреку у
примени акумулатора топлоте у којима се акумулација топлоте остварује
на рачун промене фазе радног медијума. Поред типова акумулатора
топлоте и прегледа потенцијалних, односно коришћених фазно
променљивих материјала, разматране су методе за побољшање
преношења топлоте, тј. за превазилажење проблема мале топлотне
проводљивости материјала. Као најпоузданији метод за поспешивање
преношења топлоте се показало повећање површи за размену топлоте, тј.
површи која је у контакту са фазно променљивим материјалом. Као фазно
променљиви материјал коришћен је парафин комерцијалног назива Е53.
Побољшање преношења топлоте је праћено преко смањења времена
топљења парафина, тј. повећања брзине промене фазе, односно
временског периода у коме се достиже температура промене фазе
парафина. За разлику од досадашњих истраживања, у којима је повећање
оствареног побољшања преношења топлоте посматрано у функцији од
броја ребара или неке карактеристичне димензије ребра (висина,
пречник, дужина и сл.), у овом раду је побољшање доведено у корелацију
са фактором оребрења. У оквиру дисертације је осмишљен физички
модел акумулатора топлоте испуњеног фазно променљивим материјалом
за три вредности фактора оребрења, тј. за три варијанте акумулатора
топлоте. Уведени физички модел акумулатора топлоте описан је
одговарајућим математичким моделом у који су имплементиране
претпоставке неопходне за решавање дефинисаног система једначина...
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.