Title
Tiolna grupa Cys34 humanog serum-albumina : mogućnosti i značaj određivanja u kliničkoj praksi
Creator
Jovanović, Vesna, 1970-
Copyright date
2013
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 28.12.2013.
Other responsibilities
mentor
Mandić, Ljuba, 1953-
član komisije
Vrvić, Miroslav M.
član komisije
Dimitrijević-Srećković, Vesna, 1960-
Academic Expertise
Prirodno-matematičke nauke
University
Univerzitet u Beogradu
Faculty
Hemijski fakultet
Alternative title
Cys34 thiol group of human serum albumin : possibilities and importance of determination in clinical practise
Publisher
[V. Jovanović]
Format
160 listova
description
Biohemija - Biohemija proteina / Biochemistry - Protein Biochemistry
Abstract (sr)
Humani serum albumin (HSA) ima više fizioloških funkcija, jedna od njih je
odbrana organizma od oksidativnog i/ili karbonilnog stresa. Istaknuta funkcija je posledica
prisustva jedne slobodne tiolne grupe ostatka Cys34 na površini njegovih molekula.
Određivanje sadržaja HSA-SH grupa bi moglo biti pogodno za procenu stepena
oksidativnog i/ili karbonilnog stresa u različitim patološkim stanjima. Da bi našlo primenu
u kliničkoj praksi, u prvom koraku potrebno je izolovati HSA iz seruma ili plazme, a potom
odrediti sadržaj tiolnih grupa.
Ispitivanjem pouzdanosti metode izolovanja HSA afinitetnom hromatografijom sa
Cibacron Blue (CB) iz seruma zdravih osoba i dijabetičara, i kvantifikacije tiolne grupe,
ustanovljeno je da je sadržaj HSA-SH grupa veći za 6 do 33 % od ukupnog sadržaju tiola
seruma, odnosno da je tačnost metode mala (recovery sadržaja HSA-SH grupa od 113,6 do
130,1%). Utvrđena diskrepancija nije posledica uslova izolovanja (zapremina uzorka,
karakteristike matriksa, protok kroz kolonu i vreme potrebno za izolovanje HSA i
određivanje sadržaja SH grupa), prisustva pufera za izolovanje i drugih proteina u
izolovanom HSA (čistoće od 88,4 do 91,4 %), uticaja proteina, malih molekula i jona
prisutnih u serumu na određivanje HSA-SH, već selekcije HSA molekula od strane CB
prema njihovoj konformaciji. Promena konformacije (utvrđena emisionom fluorescentnom
spektroskopijom i CD), odnosno selekcija zavisi od vrste i broja molekula masnih kiselina
(Mk) vezanih za HSA. Osim toga, priroda i broj Mk vezanih za HSA doprinose povećanju
reaktivnosti HSA-SH grupa: konstanta brzine pseudo prvog reda za reakciju HSA-SH
grupe s DTNB u CB-vezanoj-HSA frakciji (21.74x10-3 s-1) je veća u odnosu na nevezanu-
HSA frakciju (11.2x10-3 s-1), kao i u grupi dijabetičara (n=20) (20.9x10-3 s-1) u odnosu na
kontrolnu grupu (n=17) (12.9x10-3 s-1). Recovery vrednosti sadržaja Cys34-SH grupa u CBvezanim-
HSA frakcijama (od 98,5 do 101,7 %), dobijene nakon odmašćivanja HSA,
potvrdile su da metoda izolovanja HSA afinitetnom hromatografijom nije pogodna za
određivanje sadržaja HSA-SH grupa za kliničke svrhe.
U cilju postizanja veće pouzdanosti u izvođenju zaključaka o promenama sadržaja
HSA-SH grupa u različitim patološkim stanjima, optimizovana je metoda izolovanja HSA
iz seruma dvostepenim taloženjem sa amonijum-sulfatom (AS) (zasićenje AS od 54 % u
prvom i od 70 % u drugom koraku), sa prinosom HSA od 69,7 ± 4,4 %. Način taloženja
HSA (sa čvrstim AS-om ili zasićenim rastvorom AS-a) i uklanjanje AS-a iz izolovanog
preparata, ne utiče značajno na čistoću izolovanog HSA, u kojem je pored monomera
(zastupljenost 91,9 ± 3,6 %) dokazano (SDS PAG elektroforezeom i imunoblotom)
prisustvo dimera HSA (oko 10 %), tako de se predloženim postupkom izoluje HSA čistoće
oko 100 %. Predložena metoda je jednostavna, brza i jeftina, što je važno za kliničku
praksu. Omogućava precizno (RSD 3,2 %), tačno (recovery vrednost 101,2 ± 2,0 %, za
opseg fizioloških vrednosti od 0,25 do 0,75 mol-SH/mol HSA) i pouzdano (doprinos HSASH
ukupnom sadržaju tiola u serumu kod zdravih osoba iznosi 83,2 ± 5,3 %) određivanje
sadržaja HSA-SH grupa. Predložena metoda može da se primeni i za izolovanje HSA iz
plazme (ne postoji statistički značajna razlika između sadržaja Cys34-SH grupa HSA
izolovanog iz plazme ili seruma (0.574 ± 0.026; 0.570 ± 0.028 mol-SH/mol HSA, resp.).
Mogućnost i značaj određivanja sadržaja HSA Cys34-SH grupe kao markera u
kliničkoj praksi, proverena je određivanjem sadržaja HSA-SH grupa i ukupnih tiola u
grupi: obolelih od tipa 2 dijabetesa (n=23) i kontrolnoj grupi (n=17); kod trudnica sa (n=15)
i bez preeklampsije (n=15). U oba patološka stanja, kod pacijenata sa tipom 2 dijabetesa i
sa preeklampsijom, dobijeno je statistički značajno smanjenje (p<0.05) sadržaja HSA-SH
grupa i ukupnih tiola seruma u odnosu na odgovarajuće kontrolne grupe. Određivanje
sadržaja HSA Cys34-SH grupa se može primenjivati kao marker procene karbonilnog
stresa u ovim patološkim stanjima. Pored toga, nađeno je da se reaktivnost tiolne grupe
Cys34 ostatka u ovim stanjima menja, što ima važne implikacije na mogućnost modulacije
reaktivnosti (antioksidativnih svojstava) tiolne grupe pomoću suplemenata (na primer.
masnih kiselina).
Abstract (en)
Human serum albumin (HSA) has a multitude of physiological functions, and
one of them is to defend the organism against oxidative and/or carbonyl stress. This
prominent function is enabled by the presence of single free Cys34 thiol group at the
surface of HSA molecules. Determination of HSA-SH group content could be a suitable
parameter for oxidative and/or carbonyl stress level assesemnet in different pathological
states. In order to become aplicable in clinical practice, it is necessary to isolate HSA
from serum or plasma in the first, and then to determine the content of thiol group.
Monitoring of the reliability of affinity chromatography with Cibacron Blue
(CB) for HSA isolation from serum of healthy and diabetic persons, and thiol group
quantification, showed that HSA-SH group content was higher from 6 to 33% than the
total serum thiols content, i.e. that the accuracy of this method is low (HSA-SH group
content recovery ranging from 113.6 to 130.1%). This discrepancy is not caused by the
isolation conditions (sample volume, matrix charateristics, column flow and the time
needed for HSA isolation and SH group content determination), presence of buffer for
HSA isolation and other proteins in isolated HSA preparation (purity range from 88.4 to
91.4%), influence of proteins, small molecules and ions present in the serum on the
HSA-SH content determination, but the selection of HSA molecules by CB according to
their conformations. The change in conformation (determined by emmission flourescent
spectroscopy and CD), and accordingly the selection, depend on the type and the
number of fatty acid (FA) molecules bound to HSA. Besides that, the nautre and the
number of HSA bound FAs contribute to the increase in HSA-SH group reactivity:
pseudo-first order rate constant for the reaction HSA-SH group with DTNB in CB
bound fraction (21.74x10-3 s-1) is higher compared to unbound HSA fraction (11.2x10-3
s-1), as well as in diabetic group (n=20) (20.9x10-3 s-1) compared to the controls (n=17)
(12.9x10-3 s-1). Recovery values for Cys34-SH group content in CB bound HSA
fractions (from 98,5 to 101,7 %), acquired after HSA defatting, confirmed that isolation
of HSA by affinity chromatography is not suitable for determination of HSA-SH group
content in clinical practice.
A two step ammonium sulphate (AS) precipitation method for HSA isolation
from serum (AS saturation from 54% in first step and 70% in second step), with HSA
yield of 69.7±4.4%, has been optimised in order to make more reliabile conclusions
about the changes in HSA-SH group content in different pathological states. HSA
precipitation method (with solid AS or saturated AS solution) and the removal of AS
from isolated preparation, has no significant influence on the purity of isolated HSA,
where the presence of HSA dimer (about 10 %) was detected (by SDS PAG
electrophoresis and immunoblot) along with the HSA monomer (91.9%±3.6%
abundance), so the purity of isolated HSA can be regarded as 100%. The proposed
method is simple, fast and low cost, which is of greate importance for good clinical
practice. It allows for precise (RSD 3,2%), accurate (with 101,2±2% recovery for
physiological values from 0,25 to 0,75 mol -SH/mol HSA) and reliable (HSA-SH
contribution to the total serum thiols content in healthy persons is 83,2 ± 5,3 %)
determination of HSA-SH group content. In addition, proposed method could be
aplicable for isolation of HSA from plasma samples (there is no significant statistical
differrence between the HSA Cys34-SH content isolated form plasma and serum (0.574
± 0.026; 0.570 ± 0.028 mol-SH/mol HSA, resp.).
The possibility and the importance of HSA Cys34-SH content determination as a
marker in clinical practice, was tested by the determination of HSA-SH and total thiols
content in group of: patients with diabetes mellitus type II (n=23) and control group
(n=17); pregnant women with (n=15) and without preeclampsia (n=15). In both
pahtological states, in diabetic patients and pregnant women with preeclampsia, there is
a statistically significant decrease (p<0.05) in HSA-SH group content as well as in total
serum thiols content compared to appropriate controls. Determination of HSA Cys34-
SH content could be applied as a marker for carbonyl stress level assesement in these
pthological states. In addition, it was found that the reactivity of Cys34 thiol group in
these pathological states changes, which is an important implication for possible
modulation of its reactivity (antioxidant properties) by supplements (eg. fatty acids).
Authors Key words
pouzdanost određivanja tiolne grupe Cys34 HSA, reaktivnost Cys34 tiolne
grupe, izolovanje HSA iz seruma i plazme, afinitetna hromatografija, metoda dvostepenog
taloženja, masne kiseline vezane za HSA, karbonilni stres, dijabetes, preeklampsija
Authors Key words
HSA Cys34 thiol group determination reliability, Cys34 thiol group
reactivity, HSA isolation from serum and plasma, affinity chromatography, two-step
precipitation method, HSA bound fatty acid, carbonyl stress, diabetes, preeclampsia
Classification
577.112
Type
Tekst
Abstract (sr)
Humani serum albumin (HSA) ima više fizioloških funkcija, jedna od njih je
odbrana organizma od oksidativnog i/ili karbonilnog stresa. Istaknuta funkcija je posledica
prisustva jedne slobodne tiolne grupe ostatka Cys34 na površini njegovih molekula.
Određivanje sadržaja HSA-SH grupa bi moglo biti pogodno za procenu stepena
oksidativnog i/ili karbonilnog stresa u različitim patološkim stanjima. Da bi našlo primenu
u kliničkoj praksi, u prvom koraku potrebno je izolovati HSA iz seruma ili plazme, a potom
odrediti sadržaj tiolnih grupa.
Ispitivanjem pouzdanosti metode izolovanja HSA afinitetnom hromatografijom sa
Cibacron Blue (CB) iz seruma zdravih osoba i dijabetičara, i kvantifikacije tiolne grupe,
ustanovljeno je da je sadržaj HSA-SH grupa veći za 6 do 33 % od ukupnog sadržaju tiola
seruma, odnosno da je tačnost metode mala (recovery sadržaja HSA-SH grupa od 113,6 do
130,1%). Utvrđena diskrepancija nije posledica uslova izolovanja (zapremina uzorka,
karakteristike matriksa, protok kroz kolonu i vreme potrebno za izolovanje HSA i
određivanje sadržaja SH grupa), prisustva pufera za izolovanje i drugih proteina u
izolovanom HSA (čistoće od 88,4 do 91,4 %), uticaja proteina, malih molekula i jona
prisutnih u serumu na određivanje HSA-SH, već selekcije HSA molekula od strane CB
prema njihovoj konformaciji. Promena konformacije (utvrđena emisionom fluorescentnom
spektroskopijom i CD), odnosno selekcija zavisi od vrste i broja molekula masnih kiselina
(Mk) vezanih za HSA. Osim toga, priroda i broj Mk vezanih za HSA doprinose povećanju
reaktivnosti HSA-SH grupa: konstanta brzine pseudo prvog reda za reakciju HSA-SH
grupe s DTNB u CB-vezanoj-HSA frakciji (21.74x10-3 s-1) je veća u odnosu na nevezanu-
HSA frakciju (11.2x10-3 s-1), kao i u grupi dijabetičara (n=20) (20.9x10-3 s-1) u odnosu na
kontrolnu grupu (n=17) (12.9x10-3 s-1). Recovery vrednosti sadržaja Cys34-SH grupa u CBvezanim-
HSA frakcijama (od 98,5 do 101,7 %), dobijene nakon odmašćivanja HSA,
potvrdile su da metoda izolovanja HSA afinitetnom hromatografijom nije pogodna za
određivanje sadržaja HSA-SH grupa za kliničke svrhe.
U cilju postizanja veće pouzdanosti u izvođenju zaključaka o promenama sadržaja
HSA-SH grupa u različitim patološkim stanjima, optimizovana je metoda izolovanja HSA
iz seruma dvostepenim taloženjem sa amonijum-sulfatom (AS) (zasićenje AS od 54 % u
prvom i od 70 % u drugom koraku), sa prinosom HSA od 69,7 ± 4,4 %. Način taloženja
HSA (sa čvrstim AS-om ili zasićenim rastvorom AS-a) i uklanjanje AS-a iz izolovanog
preparata, ne utiče značajno na čistoću izolovanog HSA, u kojem je pored monomera
(zastupljenost 91,9 ± 3,6 %) dokazano (SDS PAG elektroforezeom i imunoblotom)
prisustvo dimera HSA (oko 10 %), tako de se predloženim postupkom izoluje HSA čistoće
oko 100 %. Predložena metoda je jednostavna, brza i jeftina, što je važno za kliničku
praksu. Omogućava precizno (RSD 3,2 %), tačno (recovery vrednost 101,2 ± 2,0 %, za
opseg fizioloških vrednosti od 0,25 do 0,75 mol-SH/mol HSA) i pouzdano (doprinos HSASH
ukupnom sadržaju tiola u serumu kod zdravih osoba iznosi 83,2 ± 5,3 %) određivanje
sadržaja HSA-SH grupa. Predložena metoda može da se primeni i za izolovanje HSA iz
plazme (ne postoji statistički značajna razlika između sadržaja Cys34-SH grupa HSA
izolovanog iz plazme ili seruma (0.574 ± 0.026; 0.570 ± 0.028 mol-SH/mol HSA, resp.).
Mogućnost i značaj određivanja sadržaja HSA Cys34-SH grupe kao markera u
kliničkoj praksi, proverena je određivanjem sadržaja HSA-SH grupa i ukupnih tiola u
grupi: obolelih od tipa 2 dijabetesa (n=23) i kontrolnoj grupi (n=17); kod trudnica sa (n=15)
i bez preeklampsije (n=15). U oba patološka stanja, kod pacijenata sa tipom 2 dijabetesa i
sa preeklampsijom, dobijeno je statistički značajno smanjenje (p<0.05) sadržaja HSA-SH
grupa i ukupnih tiola seruma u odnosu na odgovarajuće kontrolne grupe. Određivanje
sadržaja HSA Cys34-SH grupa se može primenjivati kao marker procene karbonilnog
stresa u ovim patološkim stanjima. Pored toga, nađeno je da se reaktivnost tiolne grupe
Cys34 ostatka u ovim stanjima menja, što ima važne implikacije na mogućnost modulacije
reaktivnosti (antioksidativnih svojstava) tiolne grupe pomoću suplemenata (na primer.
masnih kiselina).
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.