Title
Нумеричка симулација струјног поља ваздуха у надзвучном млазнику са препреком на излазу
Creator
Kostić, Olivera P., 1969-
Copyright date
2016
Object Links
Select license
Autorstvo 3.0 Srbija (CC BY 3.0)
License description
Dozvoljavate umnožavanje, distribuciju i javno saopštavanje dela, i prerade, ako se navede ime autora na način odredjen od strane autora ili davaoca licence, čak i u komercijalne svrhe. Ovo je najslobodnija od svih licenci. Osnovni opis Licence: http://creativecommons.org/licenses/by/3.0/rs/deed.sr_LATN Sadržaj ugovora u celini: http://creativecommons.org/licenses/by/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Committee report
Theses Type
Doktorska disertacija
description
Datum odbrane: 14. 9. 2016.
Other responsibilities
mentor
Stefanović, Zoran, 1948-
član komisije
Stupar, Slobodan, 1951-
član komisije
Simonović, Aleksandar, 1975-
član komisije
Gvozdenović, Slobodan, 1950-
član komisije
Miloš, Marko.
Academic Expertise
Tehničko-tehnološke nauke
University
Univerzitet u Beogradu
Faculty
Mašinski fakultet
Alternative title
Computational simulation of air flow supersonic nozzle with obstacle at exit
Publisher
[О. П. Костић]
Format
XIV, 129 листова
description
Mašinstvo - Tehnička fizika / Mechanical Engineering - Technical Physics
Abstract (sr)
U ovom radu se razmatra uticaj sklopnih operacija na izolacione karakteristike vakuumskih
sklopnih elemenata. Razmatraju se sledeće sklopne operacije: uklop bez struje – isklop bez
struje, uklop bez struje - uklop sa nominalnom strujom, uklop bez struje - isklop sa strujom
kratkog spoja. Pri tome se ovaj uticaj ispituje na slučajne veličine ac probojni napon,
impulsni probojni napon i na pretprobojne parametre V-4,V-5 i V-6 (dc naponi pri kojima je
pretprobojna struja 10-4 A, 10-5 A i 10-6 A). Dobijeni efekti promene karakteristika nakon
sklopnih operacija se porede sa odgovarajućim rezultatima dobijenim sa istim skopnim
elementima kondicioniranih kontakata. Tako dobijeni rezultati se tumače preko mehanizma
elektičnog pražnjenja u vakuumu. Osnovni rezultat, a ujedno i cilj rada, je ispitivanje relacija
korelacije i regresije između eksperimentalno dobijenim statističkim uzorcima slučajne
veličine ac i impulsni probojni napon i njima odgovarajućih statističkih uzoraka slučajnih
veličina predprobojnih parametara V-4,V-5 i V-6. Ispitivanje se vrši na komercijalnim
vakuumskim sklopnim elementima sa CuCr i CuBi kontaktima.
Abstract (en)
This work considers the influence of switching operations on the insulating characteristics of
vacuum circuit breakers. The following operations, all with circuit-making without current,
have been taken into account: circuit-breaking without current, circuit-breaking with nominal
current and circuit-breaking with short-circuit current. The influence of switching operations
is examined for the random variables breakdown voltage (ac and pulse) and the prebreakdown
parameters V-4, V-5, and V-6. Parameters V-4, V-5, and V-6 represent the dc voltage
at which the pre-breakdown current takes values of 10-4, 10-5, and 10-6 A, respectively.
Switching element characteristics after the switching operations are compared with the
corresponding results obtained for switching element with conditioned contacts. Obtained
results are analyzed through mechanisms of electrical discharges in vacuum. The main result
is an examination of the correlation and regression between the experimentally obtained
breakdown voltage (ac and pulse) random variable and its corresponding pre-breakdown
parameters V-4, V-5, and V-6, respectively. Statistical samples created by using this method do
not require the repetition of switching operations and therefore the dielectric strength of the
vacuum insulation is kept in its initial state. The examination is carried out on commercial
vacuum switching elements with CuCr and CuBi contacts.
Authors Key words
vakuumski sklopni elementi, sklopne operacije, pretprobojni parametar,
probojni napon, korelacija, regresija
Authors Key words
Vacuum switching element; switching operation; pre-breakdown parameter;
breakdown voltage; correlation; regression
Classification
621.45.05:533.6.011:519.6(043.3)
Type
Tekst
Abstract (sr)
U ovom radu se razmatra uticaj sklopnih operacija na izolacione karakteristike vakuumskih
sklopnih elemenata. Razmatraju se sledeće sklopne operacije: uklop bez struje – isklop bez
struje, uklop bez struje - uklop sa nominalnom strujom, uklop bez struje - isklop sa strujom
kratkog spoja. Pri tome se ovaj uticaj ispituje na slučajne veličine ac probojni napon,
impulsni probojni napon i na pretprobojne parametre V-4,V-5 i V-6 (dc naponi pri kojima je
pretprobojna struja 10-4 A, 10-5 A i 10-6 A). Dobijeni efekti promene karakteristika nakon
sklopnih operacija se porede sa odgovarajućim rezultatima dobijenim sa istim skopnim
elementima kondicioniranih kontakata. Tako dobijeni rezultati se tumače preko mehanizma
elektičnog pražnjenja u vakuumu. Osnovni rezultat, a ujedno i cilj rada, je ispitivanje relacija
korelacije i regresije između eksperimentalno dobijenim statističkim uzorcima slučajne
veličine ac i impulsni probojni napon i njima odgovarajućih statističkih uzoraka slučajnih
veličina predprobojnih parametara V-4,V-5 i V-6. Ispitivanje se vrši na komercijalnim
vakuumskim sklopnim elementima sa CuCr i CuBi kontaktima.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.