Title
Процена дозе за очно сочиво у интервентним процедурама на основу дозиметра за цело тело применом метода експерименталне и рачунарске дозиметрије
Creator
Božović, Predrag, 1985-, 67229705
Copyright date
2021
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 11.02.2021.
Other responsibilities
mentor
Ciraj-Bjelac, Olivera, 1972-, 1787751
član komisije
Vujisić, Miloš, 1974-, 13838439
član komisije
Stanković, Koviljka, 1979-, 13838695
član komisije
Stanković-Petrović, Jelena, 67298313
Academic Expertise
Tehničko-tehnološke nauke
University
Univerzitet u Beogradu
Faculty
Elektrotehnički fakultet
Alternative title
Estimation of the eye lens dose based on the whole body dosemeter in interventional procedures using experimental and computational dosimetry
Publisher
[ П. Божовић]
Format
95 strana
description
Електротехника - Нуклеарна техника / Electrical Engineering - Nuclear Engineering
Abstract (sr)
Примена X-зрачења у интервентним процедурама у значајном је порасту у погледу броја процедура и у погледу њихове комплексности, што има за последицу и повећање дозе за пацијнете и особља. Међународна комисија за заштиту од зрачења (ICRP) смањила је годишњу граничну вредност дозe за очно сочиво са 150 mSv на 20 mSv што је довело у истраживачки фокус област дозиметрије за очнг сочиво и поставила низ изазова, укључујући и развоје нових метода за мониторинг очног сочива, адекватних за имплементацију у клиничком окружењу.
Циљ овог рада је унапређење ефикасности индивидуалног мониторинга у интервеним процедурама путем одређвања оптималне позиција дозиметра за цело тело. Истраживање је базирано на претпоставци да се резулет мерења дозе путем дозиметра за цело тело који је позициониран преко заштитне кецеље, за све комбинације личних и колективних заштитних средстава може довести у вез са дозом за очно сочиво.
Монте Карло симулације коришћење су за израчунавање конверзионих коефицијената, чиме су одређене корелације дозе за очно сочиво у оперативној величини Hp(3) са дозом за цело тело исказаној у оперативној дозиметријској величини Hp(10). Вредности конверзионих фактора верификоване су компарацијом са резултатима експерименталне дозиметрије у клиничким условима. Одређени конверзиони коефицијенти који повезују Hp(3) и Hp(10) за лево/десно око износе 1.03 /0.83, 1.28 /1.06 и 1.36 /1.06, за позиције лекара, инструментарке и рендген техничара, респективно. Одговарајући фактори смањења дозе за очно сочиво за различите комбинације заштитних средстава износе 178, 5 и 6. Најбоља процена дозе за очно сочиво добија позиционирањем дозиметра за цело тело централно, у висини штитасте жлезде а резулати дају практично решење за процену дозе за очно сочиво.
Abstract (en)
The use of X-rays for interventional procedures has increased in recent years, both in terms of number of procedures and their complexity, which contributed to the increased exposure to staff and patients. The fact that International Commission on Radiological Protection (ICRP) decreased the annual dose limit for the eye lens from 150 mSv to 20 mSv caused an increased interest in eye lens dosimetry challenging the scientific committee for the development of new calibration procedures, eye lens dosemeters and eye lens monitoring procedures in order to implement them in real-life workplace situations.
The purpose of this work is to enhance efficiency of individual monitoring in interventional procedures by determination of optimal position od the whole body dosimeter, assuming that dose measured using the whole body dosimeter located above the protective tools is related to the dose to the lens the eye, for all possible combinations of protective tools and all staff members.
Monte Carlo simulations were used to calculate conversion factors from operational quantity Hp(10) to Hp(3) in order to correlate eye lens doses with whole body and thyroid doses during fluoroscopically guided interventional procedures. The conversion factors from Hp(10) to Hp(3) for left/right eye were: 1.03/0.83, 1.28/1.06 and 1.36/1.06 for positions of the first operator, nurse and radiographer, respectively. The corresponding eye lens dose reduction factors for different combinations of protective tools were 178, 5 and 6. The optimal position of the whole body dosimeter on the operator’s body is central, at the level of collar. The present study presents a pracical way to estimate the eye lens dose from the whole body dosemeters postioned above the protective tools.
Authors Key words
доза за очно сочиво, интервентне процедуре, Монте Карло симулације
Authors Key words
eye lens dosimetry, interventional procedures, Monte Carlo simulations
Classification
621.039-78:614.876:617.7(043.3)
Type
Tekst
Abstract (sr)
Примена X-зрачења у интервентним процедурама у значајном је порасту у погледу броја процедура и у погледу њихове комплексности, што има за последицу и повећање дозе за пацијнете и особља. Међународна комисија за заштиту од зрачења (ICRP) смањила је годишњу граничну вредност дозe за очно сочиво са 150 mSv на 20 mSv што је довело у истраживачки фокус област дозиметрије за очнг сочиво и поставила низ изазова, укључујући и развоје нових метода за мониторинг очног сочива, адекватних за имплементацију у клиничком окружењу.
Циљ овог рада је унапређење ефикасности индивидуалног мониторинга у интервеним процедурама путем одређвања оптималне позиција дозиметра за цело тело. Истраживање је базирано на претпоставци да се резулет мерења дозе путем дозиметра за цело тело који је позициониран преко заштитне кецеље, за све комбинације личних и колективних заштитних средстава може довести у вез са дозом за очно сочиво.
Монте Карло симулације коришћење су за израчунавање конверзионих коефицијената, чиме су одређене корелације дозе за очно сочиво у оперативној величини Hp(3) са дозом за цело тело исказаној у оперативној дозиметријској величини Hp(10). Вредности конверзионих фактора верификоване су компарацијом са резултатима експерименталне дозиметрије у клиничким условима. Одређени конверзиони коефицијенти који повезују Hp(3) и Hp(10) за лево/десно око износе 1.03 /0.83, 1.28 /1.06 и 1.36 /1.06, за позиције лекара, инструментарке и рендген техничара, респективно. Одговарајући фактори смањења дозе за очно сочиво за различите комбинације заштитних средстава износе 178, 5 и 6. Најбоља процена дозе за очно сочиво добија позиционирањем дозиметра за цело тело централно, у висини штитасте жлезде а резулати дају практично решење за процену дозе за очно сочиво.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.