Title
Neuromuscular quickness assessment - test optimization and sensitivity evaluation
Creator
Stefanović, Života, 1996-
CONOR:
53484297
Copyright date
2024
Object Links
Language
Serbian
Cobiss-ID
Theses Type
Doktorska disertacija
description
Datum odbrane: 11.10.2024.
Other responsibilities
Academic Expertise
Društveno-humanističke nauke
University
Univerzitet u Beogradu
Faculty
Fakultet sporta i fizičkog vaspitanja
Alternative title
Procena brzine neuromišićnog odgovora – optimizacija testa i ispitivanje njegove osetljivosti
Publisher
[Ž. Stefanović]
Format
65 str.
description
Fizičko vaspitanje i sport
- Nauke fizičkog vaspitanja, sporta i rekreacije / Physical Education and Sport
- Science of Physical Education, Sport and Recreation
Abstract (sr)
Skalirajući faktor brzine razvoja sile (RFD-SF) se koristi za procjenu brzine neurmoišićnog
odgovar. Međutim, standardni protokoli su obimni. Ovom studijom se procjenjivala validnost i
pouzdanost skraćenog protokola za procjenu RFD-SF kao i njegova mogućnost za identifikaciju
asimetrija donjih ekstremiteta. Trideset ispitanika je izvodilo standardni i skraćeni RFD-SF protokol
tokom tri dana. Korelaciona analiza je korišćena za istraživanje povezanosti ishoda oba protokola,
dok su Bland-Altmanovim graficima procenjivala validnost skraćenog protokola. Pouzdanost je
procijenjena korišćenjem intra-klasnog korelacionog koeficijenta, koeficijenta varijacije, tipične
greške mjerenja i t-testa za zavisne uzorke koji je dodatno korišćen za analizu osjetljivost i validnosti
za otkrivanje analize asimetrija. Fpeak – RFDpeak korelacija je skoro savršena i za dominantnu (R2
= 0,95/0,98) i za nedominantnu (R2 = 0,94/0,98) nogu oba protokola. Korelacija između RFD-SF
protokola je značajna (p < 0,001) i veoma velika za obje noge (dominantna: r = 0,71; nedominantna:
r = 0,80). Bland-Altmanovi grafici su pokazali slaganje u prihvatljivim nivoima za RFD-SF
vrijednosti. Nema značajnih razlika između protokola za dominantnu (p = 0,480, d = 0,17) i
nedominantnu nogu (p = 0,213, d = 0,31). Pouzdanost je prihvatljiva za obje noge, bez razlike između
dana za dominantnu (p = 0,393) i nedominantnu nogu (p = 0,436). Potvrđena je osjetljivost oba
protokola (p < 0,05), bez značajne razlike u identifikaciji asimetrija između ekstremiteta (p = 0,415,
d = 0,19). Rezultati sugerišu da je skraćeni protokol validna i pouzdana alternativa. Oba protokola su
osjetljiva u otkrivanju razlika između sedentarnih i aktivnih ispitanika, kao i u identifikaciji asimetrija
između udova.
Abstract (en)
The rate of force development scaling factor (RFD-SF) has been used to assess neuromuscular
quickness. However, the standard protocols are lengthy. This study evaluated the validity and
reliability of the reduced protocol to assess the RFD-SF and its validity in detecting inter-limb
asymmetries. Thirty subjects performed the standard and reduced RFD-SF protocols across three
days. Correlation analysis was used for the investigaton of association of both protocols outcomes
while Bland–Altman plots assessed reduced protocol’s validity. Reliability was evaluated using intraclass
correlation coefficient, coefficient of variation, typical error of measurement, and paired-sample
t-test which was additionally used for sensitivity and validity to detect asymmetries analysis. Fpeak
– RFDpeak correlation was nearly perfect for both dominant (R2 = 0.95/0.98) and non-dominant (R2
= 0.94/0.98) legs of both protocols respectively. Correlation between RFD-SF protocols was
significant (p < 0.001) and very large (dominant: r = 0.71; non-dominant: r = 0.80). Bland–Altman
plots showed agreement in RFD-SF values. No significant differences occured between protocols for
dominant (p = 0.480, d = 0.17) and non-dominant legs (p = 0.213, d = 0.31). Reliability was acceptable
for both legs, with no between-day difference for dominant (p = 0.393) and non-dominant legs (p =
0.436). Sensitivity of both protocols is confirmed (p < 0.05), with no significant difference in
detecting inter-limb asymmetries (p = 0.415, d = 0.19). Results suggest that the reduced protocol is a
valid and reliable alternative. Both protocols detect differences between sedentary and active subjects
and identify interlimb asymmetries.
Authors Key words
brzina razvoja sile; skalirajući faktor brzine razvoja sile; RFD-SF, protokol testiranja
RFD-SF; asimetrije
Authors Key words
rate of force development; rate of force development scaling factor; RFD-SF; RFD-SF
testing protocol; asymmetries
Classification
796.012(043.3)
Type
Tekst
Abstract (sr)
Skalirajući faktor brzine razvoja sile (RFD-SF) se koristi za procjenu brzine neurmoišićnog
odgovar. Međutim, standardni protokoli su obimni. Ovom studijom se procjenjivala validnost i
pouzdanost skraćenog protokola za procjenu RFD-SF kao i njegova mogućnost za identifikaciju
asimetrija donjih ekstremiteta. Trideset ispitanika je izvodilo standardni i skraćeni RFD-SF protokol
tokom tri dana. Korelaciona analiza je korišćena za istraživanje povezanosti ishoda oba protokola,
dok su Bland-Altmanovim graficima procenjivala validnost skraćenog protokola. Pouzdanost je
procijenjena korišćenjem intra-klasnog korelacionog koeficijenta, koeficijenta varijacije, tipične
greške mjerenja i t-testa za zavisne uzorke koji je dodatno korišćen za analizu osjetljivost i validnosti
za otkrivanje analize asimetrija. Fpeak – RFDpeak korelacija je skoro savršena i za dominantnu (R2
= 0,95/0,98) i za nedominantnu (R2 = 0,94/0,98) nogu oba protokola. Korelacija između RFD-SF
protokola je značajna (p < 0,001) i veoma velika za obje noge (dominantna: r = 0,71; nedominantna:
r = 0,80). Bland-Altmanovi grafici su pokazali slaganje u prihvatljivim nivoima za RFD-SF
vrijednosti. Nema značajnih razlika između protokola za dominantnu (p = 0,480, d = 0,17) i
nedominantnu nogu (p = 0,213, d = 0,31). Pouzdanost je prihvatljiva za obje noge, bez razlike između
dana za dominantnu (p = 0,393) i nedominantnu nogu (p = 0,436). Potvrđena je osjetljivost oba
protokola (p < 0,05), bez značajne razlike u identifikaciji asimetrija između ekstremiteta (p = 0,415,
d = 0,19). Rezultati sugerišu da je skraćeni protokol validna i pouzdana alternativa. Oba protokola su
osjetljiva u otkrivanju razlika između sedentarnih i aktivnih ispitanika, kao i u identifikaciji asimetrija
između udova.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.